Operating anti-UAV platforms in Eastern Europe and the Middle East puts one component under every constraint at once. Endurance, heat, cold, weight and cost per sortie all land on the same pack, and the 8–12 Ah cobalt-oxide LiPo that most of these airframes were designed around is close to the end of what its chemistry can give. This page answers the questions integrators actually send us about the 6S 12 Ah semi-solid-state alternative, with numbers taken from our cell specification and from a logged flight test rather than from a marketing sheet.
The cell is rated 12.0 Ah nominal and 12.3 Ah typical at 0.2C, 3.6 V, 142 ± 3 g per cell, 240 A (20C) continuous discharge and 24 A (2C) continuous charge, with internal impedance at or below 5 mΩ. That is 43.2 Wh in 142 g, or 304 Wh/kg at nominal capacity, and up to 320 Wh/kg at the light end of the weight tolerance on typical capacity.
Assembled into a 6S pack the unit weighs 908 g and carries 259.2 Wh, or 285 Wh/kg at pack level – with the same 6S voltage class and an XT90-class output, so the swap is a pack change rather than a platform redesign.
| Parameter | CoO2 LiPo 6S 8,000 mAh (baseline) | Semi-solid-state 6S 12,000 mAh |
|---|---|---|
| Configuration | 6S1P hard case | 6S pack, 12 Ah semi-solid cells |
| Nominal voltage | 22.2 V | 21.6 V |
| Capacity | 8.0 Ah | 12.0 Ah (12.3 Ah typical) |
| Nominal energy | 177.6 Wh | 259.2 Wh |
| Pack weight | 965 g | 908 g |
| Energy density at pack level | 184 Wh/kg | 285 Wh/kg |
| Max continuous discharge | 80C label (640 A) – high-rate LiCoO2 chemistry, about 260 Wh/kg at cell level | 20C continuous (240 A), about 5 kW on 6S – semi-solid chemistry, up to 320 Wh/kg at cell level |
| Cell internal impedance | Not published | ≤ 5 mΩ at AC 1 kHz |
| Max continuous charge | 1C to 5C | 2C (24 A) |
| Cycle life | Not published | ≥ 800 cycles to 80% of rated capacity |
| Discharge temperature | Not published | −30 °C to +55 °C |
One note on the 80C label, because it is where most comparisons go wrong. An 80C rating belongs to high-rate cobalt-oxide (LiCoO2) LiPo cells, and those cells pay for their burst current with energy density: in this class they sit around 260 Wh/kg at cell level. Semi-solid chemistry works the other way round. It is a density-first chemistry, the market norm for semi-solid cells is 3–5C continuous, and this platform is rated at 20C continuous (240 A), which is already at the upper end for the chemistry rather than a typical figure. That is the trade-off buyers actually face: cobalt-oxide LiPo if you need momentary burst power, semi-solid if flight time and pack weight dominate. What decides your endurance is the current the pack holds for the whole sortie, which is why the numbers below come from flight logs rather than a label on the case.
6S 12 Ah semi-solid-state pack: 908 g, 259.2 Wh, XT90-class output.
The reference build is a counter-UAS integrator’s X8 coaxial multirotor with a capture-net payload, flown on 2026-08-13 after switching from a 6S 8–12 Ah cobalt-oxide LiPo baseline. Two 6S 12 Ah packs were paralleled.
| Item | Logged reading |
|---|---|
| Pack configuration | 2 × 6S 12 Ah semi-solid-state, parallel |
| Installed pack weight | 1,846 g (single pack 908 g) |
| Energy on board | 518.4 Wh, 281 Wh/kg at pack level |
| Capacity delivered in flight | 16 Ah, about 60 A average |
| Endurance | 16 min, including one intermediate landing and take-off |
| Pack surface temperature before take-off | 28.6–31.8 °C |
| Pack surface temperature at landing | 44–64 °C |
| Motor temperature at landing | 35.5–40.9 °C |
The customer reported roughly double the endurance of their previous LiPo configuration on the same airframe. That is a customer report on their platform, not a specification: what the log establishes is 16 Ah delivered in 16 minutes, surface temperature peaking at 64 °C, motors under 41 °C at touchdown and reserve remaining in the packs.
Three field notes came out of the same test. Parallel wiring adds close to 1 kg, which raises the power the motors and ESCs must deliver at lift-off, so ramp the throttle on the first flight instead of going to full stick. The extra mass reduces useful payload, so decide whether you are buying endurance or payload before committing to a second pack. And the packs may be paralleled but never series-connected – see the wiring section below.
Field test, 2026-08-13: two 6S 12 Ah semi-solid packs in parallel on an X8 airframe.
Discharge is rated from −30 °C to +55 °C; charge is rated from 0 °C to +55 °C. The asymmetry is normal for lithium cells. At −20 °C the cell still delivers at least 80% of its initial capacity on a 1C discharge to 2.30 V, which is what makes winter sorties viable at all.
Three habits make cold operations work: store and transport packs warm at 15–25 °C rather than overnight in an unheated vehicle; pre-warm for 20–30 minutes in a warm space instead of blasting hot air at the pack; and let a cold pack return above 0 °C before it goes on the charger, even at the cost of turnaround time.
Discharge is rated to +55 °C ambient, and the cell still delivers at least 95% of initial capacity on a 1C discharge at 55 °C after storage at 60 °C. The risk in desert operations is not the rating, it is the pack running hotter than ambient inside a closed bay.
Swelling is documented rather than incidental: cell thickness is 8.0 mm at 50% state of charge and 8.5 mm at 100%, and the specification notes further swelling during high-temperature storage and operation. Allow 1–2 mm of growth room per cell stack, shade the pack, keep airflow through the bay, land with reserve, and never leave packs in a parked vehicle.
On safety: the semi-solid electrolyte reduces the free liquid fraction compared with a conventional LiPo, which lowers but does not remove fire risk. The cell has been validated for overcharge, over-discharge, external short circuit, drop, 130 °C heating, thermal cycling, crush and low pressure without fire or explosion. Treat them as lithium batteries: UN38.3 transport rules, correct storage and your existing SOP still apply.
Parallel connection is supported and is how the reference build was flown. Match packs before connecting them: same model, same capacity, same state of charge within about 0.1 V, and ideally a similar cycle count. Connect the balance leads first, pre-charge through a resistor or a spark-free connector, and size cable and connectors for the combined current rather than for one pack. A fuse on each parallel leg turns a single-pack fault into a warning instead of a fire.
Series connection is not supported. Two 6S packs in series make a 12S pack at 43.2 V, and motors and ESCs on a 6S airframe are not rated for it. The result is not a shorter flight, it is a burnt power train.
The cell is rated to at least 800 cycles before capacity falls to 80% of rated capacity, cycling at 0.5C charge and 1C discharge, and it still delivers 90% of initial capacity on a 2C discharge. Field life will be shorter if you run hot or deep, but the order of magnitude decides the commercial argument.
Cost per flight is pack price divided by usable cycles. If your LiPo fleet is retired at about 200 cycles, an 800-cycle pack returns roughly four flights for every one, before counting the sorties no longer lost to pack swaps. At 2C charge a fully discharged pack returns to usable charge in about 30 minutes, which also cuts how many packs a shift has to own.
Send these six items and we can quote against your airframe rather than a catalogue entry:
Doubling comes from real customer results on anti-UAV platforms with equivalent mounting space and similar payload, based on up to 320 Wh/kg and 20C sustained discharge. Be explicit about what is being traded: high-rate cobalt-oxide cells labelled 80C sit around 260 Wh/kg at cell level, while this semi-solid platform reaches up to 320 Wh/kg at 12.3 Ah / 139 g. Energy density and continuous rate pull against each other, so the endurance gain comes with a lower burst-current ceiling than a purpose-built high-rate LiPo. Actual endurance still depends on take-off weight, payload, weather, throttle profile and propulsion tuning. Our 16 Ah / 16 min parallel flight log is available as reference data for your simulation.
Parallel is permitted; series connection of these packs is not, because it will damage 6S-rated motors and ESCs. Two 6S 12 Ah packs were paralleled in our flight test. Expect close to 1 kg of added weight and higher motor and ESC stress: start with slow-throttle flights with a safety net fitted, and do not go straight to full throttle.
Discharge range is −30 °C to +55 °C, and at −20 °C it keeps at least 80% of initial discharge capacity. Charging must happen above 0 °C. For extreme cold, add thermal insulation to the pack enclosure and pre-warm before take-off.
Under lab conditions at 25 °C, 0.5C charge and 1C discharge, 800 cycles to 80% remaining capacity. Continuous 20C field use shortens practical life against that benchmark; ask our engineering team for an application-specific estimate based on your mission profile.
No. Different chemistries bring different voltage curves, internal resistance and ageing rates. Mixed assembly causes uneven current sharing, local overheating and a shorter, less safe pack. Build the pack from same-model cells.
240 A continuous at 20C rate, with 12 Ah nominal capacity and 142 ± 3 g cell weight. Charge is rated 24 A continuous at 2C. Note what 20C means in context: semi-solid cells are a density-first chemistry and the market norm for them is 3–5C continuous, so 20C is the upper end of what the chemistry does rather than a typical number. High-rate cobalt-oxide LiPo cells reach 80C, but at roughly 260 Wh/kg against our up to 320 Wh/kg – the two figures trade one for the other and cannot both be maximised.
At 55 °C it retains at least 95% of initial capacity on a 1C discharge. Keep packs out of prolonged direct sun, add passive heat dissipation inside the enclosure, land with reserve and let the pack cool before charging.
Overcharge, over-discharge, external short circuit, 1.5 m drop, 130 °C heating, thermal cycling between −40 °C and +85 °C, crush and low-pressure (11.6 kPa) testing, all without fire or explosion. Test reports are available to business customers under NDA.
We supply bare semi-solid cells and support pack integration technically, working with qualified pack builders for finished assemblies. Send your voltage, target capacity, payload and environmental requirements for a proposal.
Business integrators and procurement teams can request the full cell specification and the summarised flight-test record through the contact form on this site; both are released for project evaluation.
These cells are produced by Hunan Joysun New Energy Co., Ltd. in Linwu, Hunan, China. Each design is validated in-house against a documented cell specification before release – capacity, rate, impedance, low- and high-temperature performance, cycle life and abuse testing – and pack-level performance is confirmed in flight tests on real airframes. Sample packs are available ahead of volume orders so integrators can log their own flights before committing to a build.
Send your airframe, current draw, endurance target and operating temperature range, and we will come back with a pack configuration, a weight and energy estimate, and a sample plan.